@@ -32,14 +32,17 @@ class State:
Create a new PTA state.
:param name: state name
- :param power: static state power in µW
- :param power_function: parameterized state power in µW
+ :param power: static state power in µW, default 0
+ :param power_function: parameterized state power in µW, default None
"""
self.name = name
self.power = power
self.power_function = power_function
self.outgoing_transitions = {}
+ def __repr__(self):
+ return 'State<{:s}, {:.0f}, {}>'.format(self.name, self.power, self.power_function)
+
def add_outgoing_transition(self, new_transition: object):
"""Add a new outgoing transition."""
self.outgoing_transitions[new_transition.name] = new_transition
@@ -57,7 +60,7 @@ class State:
return self.power * duration
def set_random_energy_model(self, static_model=True):
- """Set a random static energy value."""
+ u"""Set a random static state power between 0 µW and 50 mW."""
self.power = int(np.random.sample() * 50000)
def get_transition(self, transition_name: str) -> object:
@@ -70,7 +73,7 @@ class State:
return self.outgoing_transitions[transition_name]
def has_interrupt_transitions(self) -> bool:
- """Check whether this state has any outgoing interrupt transitions."""
+ """Return whether this state has any outgoing interrupt transitions."""
for trans in self.outgoing_transitions.values():
if trans.is_interrupt:
return True
@@ -275,6 +278,9 @@ class Transition:
def set_random_energy_model(self, static_model=True):
self.energy = int(np.random.sample() * 50000)
+ self.duration = int(np.random.sample() * 50000)
+ if self.is_interrupt:
+ self.timeout = int(np.random.sample() * 50000)
def get_timeout(self, param_dict: dict = {}) -> float:
u"""
@@ -619,11 +625,10 @@ class PTA:
"""
Add function_name as new transition from orig_state to dest_state.
- arguments:
- orig_state -- origin state name. Must be known to PTA
- dest_state -- destination state name. Must be known to PTA.
- function_name -- function name
- kwargs -- see Transition() documentation
+ :param orig_state: origin state name. Must be known to PTA
+ :param dest_state: destination state name. Must be known to PTA.
+ :param function_name: function name
+ :param kwargs: see Transition() documentation
"""
orig_state = self.state[orig_state]
dest_state = self.state[dest_state]
@@ -678,18 +683,74 @@ class PTA:
return dict([[self.parameters[i], self.initial_param_values[i]] for i in range(len(self.parameters))])
def set_random_energy_model(self, static_model=True):
+ u"""
+ Set random power/energy/duration/timeout for all states and transitions.
+
+ Values in µW/pJ/µs are chosen from a uniform [0 .. 50000] distribution.
+ Only sets the static model at the moment.
+ """
for state in self.state.values():
state.set_random_energy_model(static_model)
for transition in self.transitions:
transition.set_random_energy_model(static_model)
+ def get_most_expensive_state(self):
+ max_state = None
+ for state in self.state.values():
+ if state.name != 'UNINITIALIZED' and (max_state is None or state.power > max_state.power):
+ max_state = state
+ return max_state
+
+ def get_least_expensive_state(self):
+ min_state = None
+ for state in self.state.values():
+ if state.name != 'UNINITIALIZED' and (min_state is None or state.power < min_state.power):
+ min_state = state
+ return min_state
+
+ def min_duration_until_energy_overflow(self, energy_granularity = 1e-12, max_energy_value = 2 ** 32 - 1):
+ """
+ Return minimum duration (in s) until energy counter overflow during online accounting.
+
+ :param energy_granularity: granularity of energy counter variable in J, i.e., how many Joules does an increment of one in the energy counter represent. Default: 1e-12 J = 1 pJ
+ :param max_energy_value: maximum raw value in energy variable. Default: 2^32 - 1
+ """
+
+ max_power_state = self.get_most_expensive_state()
+ if max_power_state.has_interrupt_transitions():
+ raise RuntimeWarning('state with maximum power consumption has outgoing interrupt transitions, results will be inaccurate')
+
+ # convert from µW to W
+ max_power = max_power_state.power * 1e-6
+
+ min_duration = max_energy_value * energy_granularity / max_power
+ return min_duration
+
+ def max_duration_until_energy_overflow(self, energy_granularity = 1e-12, max_energy_value = 2 ** 32 - 1):
+ """
+ Return maximum duration (in s) until energy counter overflow during online accounting.
+
+ :param energy_granularity: granularity of energy counter variable in J, i.e., how many Joules does an increment of one in the energy counter represent. Default: 1e-12 J = 1 pJ
+ :param max_energy_value: maximum raw value in energy variable. Default: 2^32 - 1
+ """
+
+ min_power_state = self.get_least_expensive_state()
+ if min_power_state.has_interrupt_transitions():
+ raise RuntimeWarning('state with maximum power consumption has outgoing interrupt transitions, results will be inaccurate')
+
+ # convert from µW to W
+ min_power = min_power_state.power * 1e-6
+
+ max_duration = max_energy_value * energy_granularity / min_power
+ return max_duration
+
def shrink_argument_values(self):
"""
Throw away all but two values for each numeric argument of each transition.
This is meant to speed up an initial PTA-based benchmark by
reducing the parameter space while still gaining insights in the
- effect (or nop) or individual parameters on hardware behaviour.
+ effect (or lack thereof) or individual parameters on hardware behaviour.
Parameters with non-numeric values (anything containing neither
numbers nor enums) are left as-is, as they may be distinct