diff options
author | Daniel Friesel <daniel.friesel@uos.de> | 2020-12-03 15:16:24 +0100 |
---|---|---|
committer | Daniel Friesel <daniel.friesel@uos.de> | 2020-12-03 15:16:24 +0100 |
commit | 85374727ad66b884b25ddd659600ee9317db071b (patch) | |
tree | 36c29c86feb8bfa3e3fdb7fd18d11dd7be7c7eb8 /bin | |
parent | e226cb81dd57b9810a093936e750a0e2d4512173 (diff) |
use common energytrace loader code
this also fixes a nasty off-by-one in the barcode loader
(now _load_energytrace):
wrong: interval_start_timestamp = data[:-1, 0] * 1e-6
correct: interval_start_timestamp = data[1:, 0] * 1e-6
Diffstat (limited to 'bin')
-rwxr-xr-x | bin/generate-dfa-benchmark.py | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/bin/generate-dfa-benchmark.py b/bin/generate-dfa-benchmark.py index 50f5e58..3e3454e 100755 --- a/bin/generate-dfa-benchmark.py +++ b/bin/generate-dfa-benchmark.py @@ -522,6 +522,7 @@ if __name__ == "__main__": sys.exit(2) if "msp430fr" in opt["arch"]: + # target = runner.Arch(opt["arch"], ["cpu_freq=8000000", "with_hfxt=1"]) target = runner.Arch(opt["arch"], ["cpu_freq=8000000"]) else: target = runner.Arch(opt["arch"]) |